Go to Top

ELECTRO MAGNETIC FLOWMETER

ELECTRO MAGNETIC FLOWMETER

Micro-controller based full bore type electromagnetic flow transmitter specially used for various industrial
applications. These flow transmitters accurately measures the flow rate of conductive liquids & slurries in
closed pipes. Due to simple & rigid design the flow transmitter is an obstruction less & maintenance free
instrument in place of conventional mechanical flow measuring device. The use of ‘Pulsed DC’ technology
offers highest ability & better measuring accuracy in the form of electrical signal 4 – 20 mA DC linearly
proportional to volumetric flow. The instrument is based on Faraday’s law of electro-magentic induction. A
magnetic field is generated by the instrument in the flow tube. The fluid flowing through this magnetic field
generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with
respect to measuring voltage.

26

Media : Liquids (Clear)
Line Size : 15 NB to 2000 NB.
Accuracy : +/- 0.5% F. S.
Process Temperature : 150 oC max
Type of Output : 4 to 20 mA DC, Isolated, Pulse, RS 485
Calibration Range : As per requirement (Factory Calibrated)
Process Pressure : 10 kg/cm2 max
Material of construction : Lining – Neoprene / Rubber / PTFE (Teflon) Flange – MS / SS Electrode – SS 316, SS 316 L, Hastalloy “C”,Platinum Wetted Parts – SS 316, Body – MS
Power Supply : 1) 230 V AC, 50 Hz +/- 10% 2) 24 V DC, External
Isolation : 1.4 KV between Input, Output & Power Supply
Temperature Coefficient : +/- 0.1% per oC
Display : 1) 16 x 2 LCD:2) 4 digit, 0.3” Red LED for Flow Rate Indication& 8 digit, 0.3” Red LED for Totalised Flow Indication
Repeatability : +/- 1%
Linearity : +/- 0.5%
Excitatio : Pulsed DC coil
Viscosity : 200 cp max
Dimensions :As per chart on rear
Process Connections :ASA B 16.5, Flanged
Mounting :In-Line (Horizontal or Vertical)
Line Size 15 20 25 40 50 65 80 100 150 200 250 300 350
Flow Range M /Hr 0.4-4.2 0.6-6 1-10 2.7-27 4.2-42 7.1-71 10-100 17-170 38-380 67-678 100-1000 150-1500 200-2000
F/F Distance 152 152 200 200 200 200 200 250 300 350 450 500 550